In the fields below, enter in any specifications that you need customized for your application (leave blank if no change required). Once finished, enter your information and click the “Submit” button below.

Most changes can be performed at no additional cost. Our engineering change team shall issue a customized part number and datasheet specific to your application. When applicable, a data package shall also be provided with plots and other relevant information qualifying the requested performance figures.

 

SpecificationMinTypMaxUnit
Frequency64007200MHz
Enter Required Frequency RangeMHz
Power Out (P1dB)37dBm
Enter Required P1dB PowerdBm
Power Out (PSat)37.5dBm
Enter Required PSat PowerdBm
Gain10dB
Enter Required Gain or Gain RangedB
Gain Flatness2± dB
Enter Required Gain Flatness± dB
Input Return Loss-10dB
Enter Required Input Return LossdB/VSWR
Supply Voltage1113VDC
Enter Required VDC RangeVDC
DC Current Draw (@P1dB)1.6A
Enter Current Draw limitsA

Dimensions3.75 x 1.9 x .493 Ins.
Enter Max. Allowable Size (L,W,H, in)
RF ConnectorsSMA-F/SMA-F
Enter Input / Output RF Connectors Required
DC / Control ConnectorMicro-D Conn. 9 Pin
Enter DC/Control Connector Required

  • Name Country/State


    Located in USA

    Email Phone Number